beautypg.com

C4: torque compensation, C5: speed control loop settings – Yaskawa CIMR-LU Drives User Manual

Page 170

background image

B Parameter Table

170

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

C4: Torque Compensation

C5: Speed Control Loop Settings

No.

Name

Description

Setting

C4-01

<5> Default setting is determined by the control mode (A1-02).

Torque Compensation
Gain

Sets the gain for the automatic torque (voltage) boost function and helps to produce
better starting torque.

Default: 1.00
Min: 0.00
Max: 2.50

C4-02

Torque Compensation
Primary Delay Time

Sets the torque compensation filter time.

Default:

<5>

Min: 0 ms
Max: 60000 ms

C4-03

Torque Compensation at
Forward Start

Sets torque compensation at forward start as a percentage of motor torque.

Default: 0.0%
Min: 0.0%
Max: 200.0%

C4-04

Torque Compensation at
Reverse Start

Sets torque compensation at reverse start as a percentage of motor torque.

Default: 0.0%
Min: -200.0%
Max: 0.0%

C4-05

Torque Compensation
Time Constant

Sets the time constant for torque compensation at forward start and reverse start (C4-
03 and C4-04).

Default: 10 ms
Min: 0 ms
Max: 200 ms

No.

Name

Description

Setting

C5-01

Speed Control Loop
Proportional Gain 1

Sets the proportional gain 1 of the speed control loop.

Default:

<5>

Min: 0.00
Max: 300.00

C5-02

Speed Control Loop
Integral Time 1

Sets the integral time 1 of the speed control loop.

Default:

<5>

Min: 0.000 s
Max: 10.000 s

C5-03

Speed Control Loop
Proportional Gain 2

Sets the proportional gain 2 of the speed control loop.

Default:

<5>

Min: 0.00
Max: 300.00

C5-04

Speed Control Loop
Integral Time 2

Sets the integral time 2 of the speed control loop.

Default: 0.500 s
Min: 0.000 s
Max: 10.000 s

C5-06

Speed Control Loop
Primary Delay Time
Constant

Sets the filter time constant for the time from the speed loop to the torque command
output.

Default: 0.004 s
Min: 0.000 s
Max: 0.500 s

C5-07

Speed Control Settings
Switching Speed

Sets the speed for switching between proportional gain 1, 2, 3 and integral time 1, 2,
3.

Default:

<5>

Min: 0.0%
Max: 100.0%

C5-08

Speed Control Loop
Integral Limit

Sets the speed control loop integral upper limit as a percentage of rated torque.

Default: 400%
Min: 0%
Max: 400%

C5-13

Speed Control Loop
Proportional Gain 3

Sets the proportional gain 3 of the speed control loop.

Default:

<5>

Min: 0.00
Max: 300.00

C5-14

Speed Control Loop
Integral Time 3

Sets the integral time 3 of the speed control loop.

Default:

<5>

Min: 0.000 s
Max: 10.000 s

C5-16

Speed Control Loop Delay
Time during Position Lock

Sets a delay to the torque command output from speed control loop during Position
Lock.

Default: 0.000 s
Min: 0.000 s
Max: 0.500 s

C5-17

Motor Inertia

Sets the motor inertia.

Default:

<4>

Min: 0.0001 kgm

2

Max: 600.00 kgm

2

TOEP_C710616_38F_5_0.book 170 ページ 2013年12月4日 水曜日 午前9時56分