d6: Field Forcing

d1-25

Rescue Operation Speed

Sets the speed reference during inspection operation.

Default:
10.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

d1-26

Leveling Speed

Sets leveling speed reference when d1-18 = 1 or 2.

Default: 8.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

d1-27

Motor 2 Speed Reference

Sets the speed reference for motor 2.
Note: 1. If set to 0.00, the drive will control motor 1 instead.
2. When using motor 2, be sure that the accel/decel times are set in parameters C1-12
and C1-13.

Default: 0.00 Hz
Min: 0.00 Hz
Max: 200.00 Hz

d1-28

Leveling Speed Detection
Level

Used when d1-18 = 0 or 3. If the speed reference selected is lower than d1-28, then
the drive uses the leveling speed as the speed reference.

Default: 0.0%
Min: 0.0%
Max: 100.0%

d1-29

Inspection Speed Detection
Level

Used when d1-18 = 0 or 3. If the speed reference selected is higher than d1-28 but
lower or equal to d1-29, then the drive uses inspection speed as the speed reference.

Default: 0.0%
Min: 0.0%
Max: 100.0%

<6> Setting ranges and defaults vary by the setting units determined by parameter o1-03.

Refer to

Defaults and Setting Ranges by Display Unit Selection (o1-03) on page 214

.

No.

Name

Description

Setting

d6-03

Field Forcing Selection

0: Disabled
1: Enabled

Default: 0
Min: 0
Max: 1

d6-06

Field Forcing Limit

Sets the upper limit of the excitation current command during magnetic field forcing.
A setting of 100% is equal to motor no-load current. Disabled only during DC
Injection Braking.

Default: 400%
Min: 100%
Max: 400%

No.

Name

Description

Setting