B Parameter Table

212

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

Note: Fault trace (i.e., the fault history) is not maintained when CPF00, CPF01, CPF06, CPF24, oFA00, oFb00, oFC00, Uv1, Uv2, or

Uv3 occur.

U4-31

Car Acceleration Rate

Shows the car acceleration rate.

No signal output
available

0.01
m/s

2

U4-40

Speed Reference Limit
at Rescue Operation

Displays the speed limit for Rescue Operation based on how much power the
backup battery or UPS has. Displays 0% when Rescue Operation is not being
performed.

No signal output
available

1%

U4-42

<35>

Remaining Distance

Displays the remaining distance according to the stopping method selected.

10 V:
S5-10 = 1: S5-11
S5-10 = 2: S5-12

1 mm

U4-43

<35>

Minimum Deceleration
Distance

Displays the Minimum Deceleration Distance calculated by E1-04.

No signal output
available

1 mm

U4-44

<35>

Minimum Stop
Distance

Displays the Minimum Stop Distance calculated by d1-26.

No signal output
available

1 mm

<29> Setting units are determined by the digital operator display unit selection (o1-03). When o1-03 = 0, the value is set in Hertz. When o1-03 = 4 or

5, the value is displayed in m/s. When o1-03 = 6, the value is displayed in ft/min.

<35> o1-12 (Length Units) determines the units. When o1-12 is set to 0, the unit is millimeters. When o1-12 is set to 1, the unit is inch.

<40> When checking the values of U1-03, U2-05 and U4-13 with the digital operator they are displayed in units of amperes, but when they are

checked using MEMOBUS communications, the monitor value in MEMOBUS communications is: displayed numeric value / 8192

× drive’s

rated current (A), from the condition “8192 (maximum value) = drive’s rated current (A)”.

<41> The MEMOBUS communications data is in 10 h units. If data in 1 h units are also required, refer to register number 0099H.

<42> The MEMOBUS communications data is in 10 h units. If data in 1 h units are also required, refer to register number 009BH.

No.

Name

Description

Analog Output

Level

Unit

TOEP_C710616_38F_5_0.book 212 ページ 2013年12月4日 水曜日 午前9時56分