U2: fault trace – Yaskawa CIMR-LU Drives User Manual
Page 209
![background image](https://www.manualsdir.com/files/819676/content/doc209.png)
B Parameter Table
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
209
Par
ame
te
r Ta
ble
B
■
U2: Fault Trace
No.
Name
Description
Analog Output
Level
Unit
U2-01
<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU2A0008 to 2A0033, 4A0005 to 4A0018, and 5A0003
to 5A0013 display values in 0.01 A units, while models CIMR-LU2A0047 to 2A0415, 4A0024 to 4A0605, and 5A0017 to 5A0200 display
values in 0.1 A units.
<29> Setting units are determined by the digital operator display unit selection (o1-03). When o1-03 = 0, the value is set in Hertz. When o1-03 = 4 or
5, the value is displayed in m/s. When o1-03 = 6, the value is displayed in ft/min.
<40> When checking the values of U1-03, U2-05 and U4-13 with the digital operator they are displayed in units of amperes, but when they are
checked using MEMOBUS communications, the monitor value in MEMOBUS communications is: displayed numeric value / 8192
× drive’s
rated current (A), from the condition “8192 (maximum value) = drive’s rated current (A)”.
Current Fault
Displays the current fault.
No signal output
available
–
U2-02
Previous Fault
Displays the previous fault.
No signal output
available
–
U2-03
Speed Reference at
Previous Fault
Displays the speed reference at the previous fault.
No signal output
available
0.01%
U2-04
Output Speed at
Previous Fault
Displays the output speed at the previous fault.
No signal output
available
0.01%
U2-05
Output Current at
Previous Fault
Displays the output current at the previous fault.
No signal output
available
U2-06
Motor Speed at
Previous Fault
Displays the motor speed at the previous fault.
No signal output
available
0.01%
U2-07
Output Voltage at
Previous Fault
Displays the output voltage at the previous fault.
No signal output
available
0.1 Vac
U2-08
DC Bus Voltage at
Previous Fault
Displays the DC bus voltage at the previous fault.
No signal output
available
1 Vdc
U2-09
Output Power at
Previous Fault
Displays the output power at the previous fault.
No signal output
available
0.1 kW
U2-10
Torque Reference at
Previous Fault
Displays the torque reference at the previous fault.
No signal output
available
0.1%
U2-11
Input Terminal Status at
Previous Fault
Displays the input terminal status at the previous fault. Displayed as in U1-10.
No signal output
available
–
U2-12
Output Terminal Status
at Previous Fault
Displays the output status at the previous fault. Displayed as in U1-11.
No signal output
available
–
U2-13
Drive Operation Status
at Previous Fault
Displays the operation status of the drive at the previous fault. Displayed as in
U1-12.
No signal output
available
–
U2-14
Cumulative Operation
Time at Previous Fault
Displays the cumulative operation time at the previous fault.
No signal output
available
1 h
U2-15
Soft Starter Output at
Previous Fault
Displays the run speed after a soft start when a previous fault occurred. Displayed
as in U1-16.
No signal output
available
0.01%
U2-16
Motor q-Axis Current at
Previous Fault
Displays the q-axis current for the motor at the previous fault. Displayed as in U6-
01.
No signal output
available
0.1%
U2-17
Motor d-Axis Current at
Previous Fault
Displays the d-axis current for the motor at the previous fault. Displayed as in U6-
02.
No signal output
available
0.1%
U2-20
Heatsink Temperature
at Previous Fault
Displays the temperature of the heatsink when the most recent fault occurred.
Displayed as in U4-08.
No signal output
available
1
°C
U2-21
Peak Hold Current
during Fault
Displays the peak current that occurred just prior to the previous fault.
No signal output
available
0.01 A
U2-22
Peak Hold Frequency
during Fault
Displays the output frequency when the peak current displayed in U2-21
occurred.
No signal output
available
0.01 Hz