B Parameter Table
214
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
◆ Defaults and Setting Ranges by Display Unit Selection (o1-03)
shows parameters, default settings, and setting ranges that change according to parameter o1-03, Display Unit
Selection.
Table 58 Defaults and Setting Ranges by Display Unit Selection (o1-03)
No.
<1> Automatically calculated according to the values set to o1-20, o1-21, o1-22, and E2-
/E5-
parameters.
<2> Automatically calculated according to the values set to the E2-
/E5-
parameters.
Name
o1-03 (Digital Operator Display Unit Selection)
Default
0
(0.01 Hz)
1
(0.01%)
2
(r/min)
3
(User-set)
4
(Elevator
units 1)
5
(Elevator
units 2)
6
(Elevator
units 3)
C1-01
Acceleration Ramp 1
0.00 to 600.00 s
m/s
2
0.00 to
ft/s
2
1.50 s
C1-02
Deceleration Ramp 1
C1-03
Acceleration Ramp 2
C1-04
Deceleration Ramp 2
C1-05
Acceleration Ramp 3
C1-06
Deceleration Ramp 3
C1-07
Acceleration Ramp 4
C1-08
Deceleration Ramp 4
C1-09
Fast Stop Time
C1-15
Inspection Run Deceleration
Ramp
0.00 s
C2-01
Jerk at Accel Start
0.00 to 10.00 s
m/s
3
0.00 to
ft/s
3
0.50 s
C2-02
Jerk at Accel End
C2-03
Jerk at Decel Start
C2-04
Jerk at Decel End
C2-05
Jerk below leveling speed
C1-11
Accel/Decel Switching Speed
0.00 to
[E1-04] Hz
0.00 to
100.00%
r/min
User define
0.00 to
m/s
0.00 to
ft/min
0.0%
d1-01
Speed Reference 1
0.00%
d1-02
Speed Reference 2
d1-03
Speed Reference 3
d1-04
Speed Reference 4
d1-05
Speed Reference 5
d1-06
Speed Reference 6
d1-07
Speed Reference 7
d1-08
Speed Reference 8
d1-19
Nominal Speed
100.0%
d1-20
Intermediate Speed 1
0.00%
d1-21
Intermediate Speed 2
d1-22
Intermediate Speed 3
d1-23
Releveling Speed
d1-24
Inspection Operation Speed
50.00%
d1-25
Rescue Operation Speed
10.00%
d1-26
Leveling Speed
8.00%