Flange type heat loss data – Yaskawa iQpump1000 AC Drive Quick Start User Manual
Page 91
n
Flange Type Heat Loss Data
Table 2.24 Models 2A0169 and 2A0211, 4o0139 and 4o0165, and 5A0062 to 5A0099
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc =
<1>
)
Internal
External
Total
Internal
External
Total
2A0169
200
380
1014
1394
306
816
1122
41 (90.2)
2A0211
473
1218
1691
378
976
1354
42 (92.4)
<1> Carrier frequency is set to 8 kHz in model 2A0169 and set to 5 kHz in model 2A0211.
Drive Model
Voltage
Class
Input Type
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc =
<1>
)
Internal
External
Total
Internal
External
Total
4A0139
400
6-Pulse
534
1215
1749
416
908
1324
45 (99.0)
4A0165
668
1557
2225
580
1340
1920
46 (101.2)
4T0139
<2>
12-Pulse
487
1179
1666
447
1100
1547
39 (85.8)
4T0165
<2>
624
1520
2164
629
1647
2276
40 (88.2)
<1> Carrier frequency is set to 8 kHz in model 4o0139 and set to 5 kHz in model 4A0165.
<2> Refer to manual TOEP C710616 50 for information on 12-pulse models.
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc =
<1>
)
Internal
External
Total
Internal
External
Total
5A0062
600
279
791
1070
335
1272
1607
45 (99.0)
5A0077
329
959
1288
379
1457
1836
45 (99.0)
5A0099
412
1253
1665
352
1267
1619
45 (99.0)
<1> Carrier frequency is set to 8 kHz in models 5A0062 and 5A0077 and set to 5 kHz in model 5A0099.
2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss
YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide
91
2
Mechanical Installation