Register No.
Contents
00D2H
bit 0
ASIC Start-up Error (CPF32)
bit 1
Watch-dog Error (CPF33)
bit 2
ASIC Power/Clock Error (CPF34)
bit 3
External A/D Converter Error (CPF35)
bit 4 to 7
Reserved
bit 8
Control Circuit Error (CPF40)
bit 9
Control Circuit Error (CPF41)
bit A
Control Circuit Error (CPF42)
bit B
Control Circuit Error (CPF43)
bit C
Control Circuit Error (CPF44)
bit D
Control Circuit Error (CPF45)
bit E, F
Reserved
00D3H to 00D7H
oFA0x Contents (CN5-A)
00D8H
oFA0x Contents (CN5-A)
bit 0
Option Compatibility Error (oFA00)
bit 1
Option not properly connected (oFA01)
bit 2
Same type of option card already connected (oFA02)
bit 3, 4
Reserved
bit 5
A/D Conversion Error (oFA05)
bit 6
Option Response Error (oFA06)
bit 7 to F
Reserved
00D9H
oFA1x Contents (CN5-A)
bit 0
Option RAM Fault (oFA10)
bit 1
Option Operation Mode Fault (SLMOD) (oFA11)
bit 2
Drive Receive CRC Error (oFA12)
bit 3
Drive Receive Frame Error (oFA13)
bit 4
Drive Receive Abort Error (oFA14)
bit 5
Option Receive CRC Error (oFA15)
bit 6
Option Receive Frame Error (oFA16)
bit 7
Option Receive Abort Error (oFA17)
bit 8 to F
Reserved
00DAH to 00DBH
Reserved
00DBH
oFA3x Contents (CN5-A)
bit 0
Comm. ID Error (oFA30)
bit 1
Model Code Error (oFA31)
bit 2
Sumcheck Error (oFA32)
bit 3
Comm. option timeout waiting for response (oFA33)
bit 4
MEMOBUS Timeout (oFA34)
bit 5
Drive timeout waiting for response (oFA35)
bit 6
CI Check Error (oFA36)
bit 7
Drive timeout waiting for response (oFA37)
bit 8
Control Command Selection Error (oFA38)
bit 9
Drive timeout waiting for response (oFA39)
bit A
Control Response Selection 1 Error (oFA40)
bit B
Drive timeout waiting for response (oFA41)
bit C
Control Response Selection 2 Error (oFA42)
bit D
Control Response Selection Error (oFA43)
bit E, F
Reserved
C.9 MEMOBUS/Modbus Data Table
YASKAWA TOEP YAIP1W 01B YASKAWA AC Drive - iQpump1000 Quick Start Guide
437
C
MEMOBUS/Modbus Communications