Flange type heat loss data – Yaskawa iQpump1000 AC Drive Quick Start User Manual
Page 102

n
Flange Type Heat Loss Data
Table 2.28 Models 2A0360 and 2A0415, 4o0250 to 4o0362, and 5A0192 and 5A0242
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc =
<1>
)
Internal
External
Total
Internal
External
Total
2A0360
200
894
2698
3592
783
2564
3347
108 (238)
2A0415
954
2672
3626
954
2672
3626
–
<1> Carrier frequency is set to 5 kHz in model 2A0360 and set to 2 kHz in model 2A0415.
Drive Model
Voltage
Class
Input Type
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc =
<1>
)
Internal
External
Total
Internal
External
Total
4A0250
400
6-Pulse
803
2379
3182
715
2360
3075
106 (233)
4A0296
905
2448
3353
787
2391
3178
112 (246)
4A0362
1130
3168
4298
985
3075
4060
117 (257)
4T0250
<2>
12-Pulse
729
2305
3034
663
2308
2971
90 (198)
4T0296
<2>
772
2308
3080
694
2295
2989
95 (209)
4T0362
<2>
874
3168
4042
788
3075
3863
97 (214)
<1> Carrier frequency is set to 5 kHz in models 4o0250, 4o0296, and 4T0362 and set to 2 kHz in model 4A0362.
<2> Refer to manual TOEP C710616 50 for information on 12-pulse models.
Drive Model
Voltage
Class
Heat Loss (W)
Wt. kg (lb)
ND (Fc = 2 kHz)
HD (Fc = 2 kHz)
Internal
External
Total
Internal
External
Total
5A0192
600
769
2420
3189
648
2114
2762
117 (257)
5A0242
1131
3100
4231
896
2526
3422
117 (257)
2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss
102