beautypg.com

Yaskawa Yasnac PC NC User Manual

Page 329

background image

YASNAC PC NC Operating Manual

APPENDIX 3: Parameter Tables

A3 - 103

Operation

Address

Bit

Description

Register

Units

Minimum

Value

Maximum

Value

Long Description

7

1

Single block in Macro

1:

Interrupted by single block stop

0:

Not interrupted by single block stop

0

1

Operation instructions and
control instructions in user
macro.

20

0

Macro edit/display lock for O8000

1:

Prohibited

0:

Permitted

0

1

Edit, display, and input/output
operation of part programs
O8000 to O8999

21

0

Macro edit lock for O8000

1:

Prohibited

0:

Permitted

0

1

Edit, input/output operation of
part programs O8000 to
O8999

22

0

Macro edit lock for O9000

1:

Prohibited

0:

Permitted

0

1

Edit, input/output operation of
part programs O9000 to
O9999

3002

0

Clearing MDI buffer at completion of MDI

1:

Not cleared

0:

Cleared

0

1

Clearing MDI buffer by pro-
gram reset if M02 or M30 is
specified at the completion of
MDI program

1

Clearing MDI buffer by reset operation

1:

Not cleared

0:

Cleared

0

1

2

Start position of MDI program

1:

Beginning of the MDI program

0:

Present cursor position

0

1

3004

0

Edit/display/output of O9000 to O9999 pro-
gram

1:

Prohibited

0:

Permitted

0

1

6

Work position, Work shift, Tool off change
in EDIT, LOCK

1:

Prohibited

0:

Permitted

0

1

3005

1

Clearing of the program numbers at power
ON

1:

Not cleared

0:

Cleared

0

1

4

Auto edit of program number when

0:

Not edited

1:

Edited automatically

0

1

3007

2

Program upload operation during EDIT
LOCK

0: Prohibited

1: Permitted

0

1

3

Program download operation during EDIT
LOCK

0: Prohibited

1: Permitted

0

1