Yaskawa Yasnac PC NC User Manual
Page 329

YASNAC PC NC Operating Manual
APPENDIX 3: Parameter Tables
A3 - 103
Operation
Address
Bit
Description
Register
Units
Minimum
Value
Maximum
Value
Long Description
7
1
Single block in Macro
1:
Interrupted by single block stop
0:
Not interrupted by single block stop
0
1
Operation instructions and
control instructions in user
macro.
20
0
Macro edit/display lock for O8000
1:
Prohibited
0:
Permitted
0
1
Edit, display, and input/output
operation of part programs
O8000 to O8999
21
0
Macro edit lock for O8000
1:
Prohibited
0:
Permitted
0
1
Edit, input/output operation of
part programs O8000 to
O8999
22
0
Macro edit lock for O9000
1:
Prohibited
0:
Permitted
0
1
Edit, input/output operation of
part programs O9000 to
O9999
3002
0
Clearing MDI buffer at completion of MDI
1:
Not cleared
0:
Cleared
0
1
Clearing MDI buffer by pro-
gram reset if M02 or M30 is
specified at the completion of
MDI program
1
Clearing MDI buffer by reset operation
1:
Not cleared
0:
Cleared
0
1
2
Start position of MDI program
1:
Beginning of the MDI program
0:
Present cursor position
0
1
3004
0
Edit/display/output of O9000 to O9999 pro-
gram
1:
Prohibited
0:
Permitted
0
1
6
Work position, Work shift, Tool off change
in EDIT, LOCK
1:
Prohibited
0:
Permitted
0
1
3005
1
Clearing of the program numbers at power
ON
1:
Not cleared
0:
Cleared
0
1
4
Auto edit of program number when
0:
Not edited
1:
Edited automatically
0
1
3007
2
Program upload operation during EDIT
LOCK
0: Prohibited
1: Permitted
0
1
3
Program download operation during EDIT
LOCK
0: Prohibited
1: Permitted
0
1