alarm.210

In user macro, the value of constant is outside the allowable range.

alarm.211

The number of cancel codes for G67 is too many.

alarm.212

There is an error in the format.

alarm.213

A value not defined as a variable number is used.

alarm.214

A variable used in replace statement is the variable which cannot be used for this operation.

alarm.215

The nesting level of “[ ]” exceeds the allowable limit.

alarm.216

The nesting level of macro program call exceeds the allowable limit.

alarm.217

DO - END is not used in pairs.

alarm.218

The numbers of brackets “[“ and ”]” do not agree with each other.

alarm.219

In “DO M”, 1 (M, 3 is not satisfied.)

alarm.220

In “GOTO n”, “n” is outside the allowable range or “n” is not found.

alarm.221

In a macro program, division by “O” is executed.

alarm.222

Square root of a negative value.

alarm.223

Floating point data exceeds the allowable range.

alarm.224

In modal call (G66), axis command is specified with M99 return designation.

alarm.225

Overflow has occurred with operation stack.

alarm.226

Execution of the following functions was impossible: ASIN, ACOS, LN, SQRT.

alarm.227

Overflow has occurred during conversion into integer.

alarm.228

Overflow has occurred with the input data for the BCD function.

alarm.229

There is an error in the format of the BIN function.

alarm.230

Overflow has occurred as the result of execution of the EXP function.

alarm.240

Reference point return has not been completed with the axis for which G29, G30 is designated.

alarm.241

Reference point return is invalid for the axis for which G28 is designated.

alarm.250

An illegal code has been designated in a solid tap program.

alarm.255

An C command is designated for the spindle in the spindle control mode.

alarm.256

An S command is designated for the spindle in the C-axis control mode.

alarm.260

*There is no P or Q command in the M98 block.& *There is no P command in the G65/G66, G25 block.&
*Both

G25 and M98/M99 are designated in the same block.

alarm.261

Nesting level of M98 subprogram call or G25 exceeds the allowable limit.

alarm.262

In a program that calls a micro program by G, M, or T code (M98, M99, G65, G66, G25), the designated pro-
gram number or sequence number is not found.

alarm.263

An attempt was made to start a program by executing address search after buffering subprogram or macro
call.

Alarm No.

Description