beautypg.com

Appendix 2.2 pc nc alarm table – Yaskawa Yasnac PC NC User Manual

Page 207

background image

YASNAC PC NC Operating Manual

Appendix 2: Alarm Tables

A2 - 3

APPENDIX 2.2

PC NC ALARM TABLE

Alarm No.

Description

alarm.25

There is an error in the setting of parameters.

alarm.50

The parameter which is made valid after power off/on operation has been set.

alarm.51

The parameter which is made valid only when the program area is cleared has been set.

alarm.61

There is an error in the designation of data in external data input.

alarm.62

The program designated by the external data number search is not found.

alarm.100

Overflow has occurred with one-block buffer (128 characters).

alarm.101

There is no data specified following an address, or the data is specified without address.

alarm.102

“-” or “.” is not used correctly.

alarm.103

Illegal character is specified in the significant information area.

alarm.104

Overflow has occurred with the input numerical value (more than 9 characters).

alarm.105

An axis not defined as an axis is designated.

alarm.106

The same address is designated more than one time in one block.

alarm.107

Nesting of “( )” error, “)” is used without “)”, “(“and”)” are not used in pairs.

alarm.110

More than one M code is designated in one block although multiple M code option is not selected.

alarm.111

The number of digits in the specified M code is larger than the allowable limit.

alarm.112

M90 and M91 are not designated in a block without other commands. There is no P command in the M91
block.

alarm.113

There is an error in the designation of an internal M code.

alarm.114

M90/M91 is designated although designation is not allowed.

alarm.115

There is an error in the M191 command.

alarm.116

M93 is designated although designation is not allowed.

alarm.125

M, S, or T is designated although designation of M, S, or T is not allowed.

alarm.126

There is no M02/M30 command in memory mode or tape mode operation.

alarm.127

*In the mirror image mode, an illegal G is designated.& *Mirror image is turned ON in the mirror image pro-
hibited mode.

alarm.130

More than one S code is designated in one block although multiple S control option is not selected.

alarm.131

The number of digits in the specified S code is larger than the allowable limit.

alarm.140

The number of digits in the specified T code is larger than the allowable limit.

alarm.144

The number of digits in the specified B code is larger than the allowable limit.

alarm.150

Offset number is too large.

alarm.151

Offset number specified in H/D switching is too large.

alarm.152

Offset number H is not designated.

alarm.160

An illegal G code is designated. Or a G code for which the corresponding option is not selected is designated