Using the basic-bootware menu, Modifying serial port parameters – H3C Technologies H3C S12500 Series Switches User Manual
Page 203

191
Using the BASIC-BOOTWARE menu
To access the BASIC-BOOTWARE menu:
1.
Power on the device.
DDR2 SDRAM test successful.
Press Ctrl+T to start five-step full RAM test...
Press Ctrl+Y to start nine-step full RAM test...
System is starting...
Press Ctrl+D to access BASIC-BOOTWARE MENU
2.
Press Ctrl + D within 3 seconds after the "Press Ctrl+D to access BASIC-BOOTWARE MENU"
prompt message appears. If you fail to do this within the time limit, the system starts to run the
extended BootWare segment.
======================
|<1> Modify Serial Interface Parameter |
|<2> Update Extend BootWare |
|<3> Update Full BootWare |
|<4> Boot Extend BootWare |
|<5> Boot Backup Extend BootWare |
|<0> Reboot |
============================================================================
Enter your choice(0-5):
Table 22 BASIC-BOOTWARE menu options
Option Task
<1> Modify Serial Interface Parameter
Change the baud rate of the console port.
<2> Update Extend BootWare
Update the extended BootWare segment.
If the extended segment has corrupted, choose this option to
repair it.
<3> Update Full BootWare
Update the entire BootWare, including the basic segment
and the extended segment.
<4> Boot Extend BootWare
Run the primary extended BootWare segment.
<5> Boot Backup Extend BootWare
Run the backup extended BootWare segment.
<0> Reboot
Reboot the device.
Modifying serial port parameters
When using the console port to access the system, make sure the port parameters are consistent with the
serial port settings on the configuration terminal, including the baud rate, data bits, parity check, stop
bits, flow control, and emulation. If the settings are inconsistent, communication will fail. For more
information, see login management configuration in Fundamentals Configuration Guide.
With BootWare, you can change the baud rate. H3C recommends that you change the default baud rate
(9600 bps) to a higher baud rate for faster file transfer before downloading a software image file with
XMODEM through the console port.
To change the baud rate of the console port:
- H3C S12500-X Series Switches H3C S9800 Series Switches H3C S9500E Series Switches H3C S5560 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C SR8800 H3C SR6600-X H3C SR6600 H3C MSR 5600 H3C MSR 50 H3C MSR 3600 H3C MSR 30 H3C MSR 2600 H3C MSR 20-2X[40] H3C MSR 20-1X H3C MSR 930 H3C MSR 900 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C WA3600 Series Access Points H3C WA2600 Series WLAN Access Points H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C S10500 Series Switches