Configuration procedure, Configuring the exception handling method – H3C Technologies H3C S12500 Series Switches User Manual
Page 174

162
end the final line with a delimiter that is the same as the start delimiter. For example, you can
configure the banner “Have a nice day. Please input the password.” as follows:
[System] header shell A
Please input banner content, and quit with the character 'A'.
Have a nice day.
Please input the password.A
{
Method 3—After you type the final keyword, type the start delimiter and part of the banner
message and press Enter. At the system prompt, enter the rest of the banner and end the final
line with a delimiter that is the same as the start delimiter. Using this method, you can use any
character as the start and end delimiters but must make sure that it is not the same as the end
character of the message text in the first line. For example, you can configure the banner “Have
a nice day. Please input the password.” as follows:
[System] header shell AHave a nice day.
Please input banner content, and quit with the character 'A'.
Please input the password.A
Configuration procedure
To configure a banner:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the incoming
banner.
header incoming text Optional.
3.
Configure the login banner.
header login text Optional.
4.
Configure the legal banner.
header legal text Optional.
5.
Configure the shell banner.
header shell text Optional.
6.
Configure the MOTD banner. header motd text Optional.
Configuring the exception handling method
In standalone mode, when the system detects any software abnormality on the active main processing
unit (MPU), it handles the situation with one of the following methods:
•
reboot—The device automatically reboots the failed active MPU to recover from the error condition.
•
maintain—The device stays in the error condition so you can collect complete data, including error
messages, for diagnosis. Using this method, you must manually reboot the device.
The system always reboots a card or the auxiliary CPU system when an exception occurs to them.
To configure the exception handling method:
Step Command
Remarks
1.
Enter system view.
system-view N/A
- H3C S12500-X Series Switches H3C S9800 Series Switches H3C S9500E Series Switches H3C S5560 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C SR8800 H3C SR6600-X H3C SR6600 H3C MSR 5600 H3C MSR 50 H3C MSR 3600 H3C MSR 30 H3C MSR 2600 H3C MSR 20-2X[40] H3C MSR 20-1X H3C MSR 930 H3C MSR 900 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C WA3600 Series Access Points H3C WA2600 Series WLAN Access Points H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C S10500 Series Switches