Upgrading fan monitor software – H3C Technologies H3C S12500 Series Switches User Manual
Page 131

119
This task does not apply to the PSE9000 power module. To identify the power module model, use the
display power-supply command (see "Device management commands").
To ensure a successful upgrade, follow these guidelines:
•
The upgrade file must be saved on the switch that holds the power monitoring module to be
upgraded.
•
In an IRF fabric, save the upgrade file on the active MPU that is in the same chassis as the power
monitoring module. If you are upgrading for the master device, you can save the file on its active
MPU or standby MPU.
•
Make sure no one performs any of the following operations during the upgrade:
{
Perform an active/standby switchover.
{
Power off the switch.
{
Reboot or swap the active MPU.
To upgrade the software of a power monitoring module, perform one of the following tasks in user view:
Task Command
Upgrade the power monitor software (in standalone
mode).
pmu update [ file file-url ] pmu-id
Upgrade the power monitor software (in IRF mode).
pmu update [ file file-url ] chassis chassis-number
pmu-id
Upgrading fan monitor software
To ensure a successful upgrade, follow these guidelines:
•
This task is available only for fan trays that use software version 103 and CPLD 002 (or above). To
display this information, use the display fan verbose command.
•
In an IRF fabric, save the upgrade file on the active MPU that is in the same chassis as the fan tray
you are upgrading. If you are upgrading for the master device, you can save the file on its active
MPU or standby MPU.
•
Make sure no one performs any of the following operations during the upgrade:
{
Remove the fan tray before the system displays the upgrade completed message.
{
Perform an active/standby switchover.
{
Power off the switch.
{
Reboot or swap the active MPU.
•
After the fan update command is executed for one fan tray, you must reinstall the fan tray before
upgrading the other fan tray.
To upgrade the fan monitor software of a fan tray:
- H3C S12500-X Series Switches H3C S9800 Series Switches H3C S9500E Series Switches H3C S5560 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C SR8800 H3C SR6600-X H3C SR6600 H3C MSR 5600 H3C MSR 50 H3C MSR 3600 H3C MSR 30 H3C MSR 2600 H3C MSR 20-2X[40] H3C MSR 20-1X H3C MSR 930 H3C MSR 900 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C WA3600 Series Access Points H3C WA2600 Series WLAN Access Points H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C S10500 Series Switches