Issu upgrade steps and states – H3C Technologies H3C S12500 Series Switches User Manual
Page 143

131
ISSU upgrade steps and states
During the ISSU upgrade process, the switch might be in one of the states shown in
.
Table 16 ISSU state description
State Description
Init
No ISSU states or an ISSU upgrade has completed.
Load
The standby MPU or a member switch is being upgraded or has been
upgraded. The rollback timer is created successfully and runs correctly.
Switching
Interface cards are being upgraded or the system is performing a rollback.
Switchover
Interface cards have been upgraded, and the upgraded standby MPU or
member switch has become the new active MPU or master.
Accept
The upgrading operation of the new active MPU or the new master is accepted,
and the rollback timer is automatically deleted. No auto-rollback is performed
during this ISSU upgrade process.
Commit (the state of the
standby MPU)
Multiple standby MPUs or member switches are available in the system, and at
least one standby MPU or member switch has not upgraded to the new version.
In this state, neither manual nor auto-rollback is performed during this ISSU
upgrade process.
ISSU states correspond to ISSU operations. The ISSU state changes and operations during the upgrade
process might vary depending on the software version compatibility state between the upgrade and the
current version. See
The ISSU upgrade process proceeds step by step, and each operation corresponds to an ISSU state.
Except for the state change caused by expiration of the rollback timer, the ISSU state changes only when
you execute the corresponding command. For example, in
, "Upgrade the global standby
MPU", "Switchover & upgrade interface cards", "Accept the upgrade of the new global active MPU",
and "Upgrade another MPU" are the ISSU operations, and are completed by executing the issu load,
issu run switchover, issu accept, and issu commit commands respectively. Rollback is also an ISSU
operation, which can be triggered by either the expiration of the rollback timer or the execution of the
issu rollback command.
The arrows in the figures indicate the directions of state changes. For example, if you execute the issu
load command on the switch in the init state, the local standby MPU of the master upgrades to the new
version and its ISSU state changes to load. If you execute the issu rollback command on the IRF member
switch in load state, the local standby MPU of the master rolls back to the previous version and the ISSU
state changes back to init.
- H3C S12500-X Series Switches H3C S9800 Series Switches H3C S9500E Series Switches H3C S5560 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C SR8800 H3C SR6600-X H3C SR6600 H3C MSR 5600 H3C MSR 50 H3C MSR 3600 H3C MSR 30 H3C MSR 2600 H3C MSR 20-2X[40] H3C MSR 20-1X H3C MSR 930 H3C MSR 900 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C WA3600 Series Access Points H3C WA2600 Series WLAN Access Points H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C S10500 Series Switches