After capturing the trace, users can download it for basic analysis. Or you can contact Grandstream

Technical support in the following link for further assistance if the issue is not resolved.

http://www.grandstream.com/index.php/support

E&M IMMEDIATE RECORD TRACE

Before capturing the trace for E&M, user could configure “Record Direction” and “Record File Mode".

“Record File Mode” can be separate (one record per direction) or mix. Then click on “Start” to start to

capture.

Figure 186: E&M Immediate Record Trace

SERVICE CHECK

Enable Service Check to periodically check UCM6510. Check Cycle is configurable in seconds and the

default setting is 60 sec. Check Times is the maximum number of failed checks before restart the

UCM6510. The default setting is 3. If there is no response from UCM6510 after 3 attempts (default) to

check, current status will be stored and UCM6510 will be restarted.

Figure 187: Service Check