Advance Settings
Coding
Select B8ZS or AMI. The default setting is B8ZS for T1.
OutgoingDialDelay
The option is only valid for E&M Wink signaling. The dial delay interval
after received WINK event in an outgoing call. The default value is 200ms.
rxwink
Configure receive wink timing. The default setting is 300ms.
DIGITAL TRUNK CONFIGURATION
After configuring digital hardware, go to web GUI->PBX->Basic/Call Routes->Digital Trunks.
• Click on "Create New Digital Trunk" to add a new digital trunk.
• Click on
to configure detailed parameters for the digital trunk.
• Click on
to configure Direct Outward Dialing (DOD) for the digital Trunk.
• Click on
to delete the digital trunk.
The digital trunk parameters are listed in the table below.
Table 54: Digital Trunk Configuration Parameters
Trunk Name
Configure trunk name to identify the digital trunk.
Channel Group
Configure the digital channel group used by the trunk.
Hide CallerID
Configure to hide outgoing caller ID. The default setting is "No".
Keep Trunk CID
If enabled, the trunk CID will not be overridden by extension's CID when
the extension has CID configured. The default setting is "No".
Caller ID
Configure the Caller ID. This is the number that the trunk will try to use
when making outbound calls. For some providers, it might not be possible
to set the CallerID with this option and this option will be ignored.
When making outgoing calls, the following rules are used to determine
which CallerID will be used if they exist:
• The CallerID configured for the extension will be looked up first.
• If “Keep Trunk CID” is enabled, the CallerID configured for the trunk
will be used.
• If the above two are missing, the "Global Outbound CID" defined in
web GUI->PBX->Internal Options->General will be used.