Syslog, Figure 181: reset and reboot – Grandstream UCM6510 User Manual User Manual
Page 307

Firmware Version 1.0.2.5
UCM6510 IP PBX User Manual
Page 306 of 313
•
User Data: All the data including voicemail, recordings, IVR Prompt, Music on Hold, CDR and backup
files will be cleared.
•
All: All the configurations and data will be reset to factory default.
Figure 181: Reset and Reboot
SYSLOG
On the UCM6510, users could dump the syslog information to a remote server under web
GUI->Maintenance->Syslog. Enter the syslog server hostname or IP address and select the module/level
for the syslog information.
The default syslog level for all modules is "error", which is recommended in your UCM6510 settings
because it can be helpful to locate the issues when errors happen.
Some typical modules for UCM6510 functions are as follows and users can turn on "notic" and "verb"
levels besides "error" level.
pbx: This module is related to general PBX functions.
chan_sip: This module is related to SIP calls.
chan_dahdi: This module is related to analog calls (FXO/FXS).
app_meetme: This module is related to Conference Bridge.
--------------------------------------------------------------------------------------------------------------------------------------------
Note:
Syslog is usually for debugging and troubleshooting purpose. Turning on all levels for all syslog modules is
not recommended for daily usage. Too many syslog print might cause traffic and affect system
performance.
--------------------------------------------------------------------------------------------------------------------------------------------