The ATCA-7350 utilizes two SAS internal cable receptacle connectors. The connector provides
contact for the power pins and only the primary physical link. The pinout and pin assignment
information are as follow:

Figure 3-5

PINOUT of SAS Connector

Table 3-8 SAS Connector Pin Assignments

Segment

PIN

Name

Description

Primary Signals

S1

GROUND

Connected to the logic Ground of ATCA-7350

S2

TP+

Primary Transmitting Pair. Driven by SAS controller of
ATCA-7350.

S3

TP-

S4

GROUND

Connected to the logic Ground of ATCA-7350

S5

RP-

Primary Receiving Pair. Driven by the target device.

S6

RP+

S7

GROUND

Connected to the logic Ground of ATCA-7350