A.10.5 no information is displayed on the monitor, Troubleshooting – Artesyn ATCA-7350 Installation and Use (September 2014) User Manual
Page 181

Troubleshooting
ATCA-7350 Installation and Use (6806800G59G)
181
Solution
To solve the problem, proceed as follows:
1. If monitor self-test indicates that the monitor works normally, consider the position of the
monitor apart. The magnetic field around other devices (such as transformers, electronic
devices, fluorescent lights, and other monitors) may cause screen jitters, image
fluctuation, or unreadable, rolling or twisted image.
2. When you move a color monitor, the color of the screen may be distorted. Move the device
and monitor. Make sure that the distance between them is at least 305 mm.
3. Turn on the monitor. If the problem persists, replace the monitor or ATCA-7350. For details
on how to replace the monitor, refer to the document shipped with the monitor that you
use.
For details on how to replace the ATCA-7350, see
Installing and Removing the Blade
.
A.10.5 No Information Is Displayed on the Monitor
Description
The ATCA-7350 LEDs indicate normal operation and no alarm is generated. However, no
information is displayed on the monitor.
Solution
To solve the problem, proceed as follows:
1. Make sure that:
The RTM-ATCA-7x50 is inserted properly.
The upper and lower ejector handles are fully closed.
The LEDs are in normal state.
2. Make sure that the cable connectors of the monitor contact well.
3. Check whether the DIMM is inserted.
4. If the DIMM is inserted, check whether it is inserted in the memory slot firmly.
5. If the problem persists, replace the DIMM with a new one.
For details, see
.