beautypg.com

4 sol firmware upgrade – Artesyn ATCA-7350 Installation and Use (September 2014) User Manual

Page 163

background image

Software Upgrade

ATCA-7350 Installation and Use (6806800G59G)

163

SDR and FRU Upgrade

Follow the steps below.

1. Boot Linux on the ATCA-7350 blade or on a host blade with network access to a

'rmcp' capable shelf manager hosting the target ATCA-7350 to get a Linux shell
prompt.

2. Upgrade the firmware using the update script:

$ ./fw_upd.sh [-U ] [-P ] [-n ]

[-s] [-t ] -i
Example:
update method via ’rmcp’ server
$ ./fw_upd.sh -i fru_sdr -t 172.17.0.8
default update method using onboard IPMI KCS interface
$ ./fw_upd.sh -i fru_sdr

8.3.4

SOL Firmware Upgrade

This section describes the SOL firmware upgrade via fw_upd.sh. It is part of the atca-
7350-fw-x.y.z-r

rpm package. Please ask your local sales representative for obtaining this

package.

SOL Firmware Upgrade

Follow the steps below.

1. Boot Linux on the ATCA-7350 blade or on a host blade with network access to a

'rmcp' capable shelf manager hosting the target ATCA-7350 to get a Linux shell
prompt.

2. Upgrade the firmware using the update script:

$ ./fw_upd.sh [-U ] [-P ] [-n

number>] [-s] [-t ] -i
Example:
update method via ’rmcp’ server
$ ./fw_upd.sh -i sol_fw -t 172.17.0.8