2 client setup – Artesyn ATCA-7350 Installation and Use (September 2014) User Manual

Page 111

background image

System Management

ATCA-7350 Installation and Use (6806800G59G)

111

5.4.2

Client Setup

The client receives serial data from the ATCA-7350 with the SOL function. The data is displayed
on the client console (IPMITOOL).

Ensure that the ATCA-7350 has the following firmware/OS versions loaded:

RedHat RHEL 4.0

RedHat RHEL 5.1 or higher

In this example, ipmitool is running on another blade in the same chassis.

Configure the Ethernet Port

For RedHat RHEL:

1. Configure IP address of the Ethernet port:

vi /etc/sysconfig/network-scripts/ifcfg-eth0

ifcfg-eth0

BOOTPROTO=static

IPADDR=10.90.90.113

NETMASK=255.0.0.0

ONBOOT=yes

TYPE=Ethernet

DHCP_HOSTNAME=rhel4u3

2. Execute this command to restart the network:

service network restart

ipmitool needs to be installed on a Linux computer located anywhere in the network.