beautypg.com

7 remote access configuration submenu, Table 6-11, Mps configuration submenu – Artesyn ATCA-7350 Installation and Use (September 2014) User Manual

Page 129: Table 6-12, Remote access configuration submenu, Bios

background image

BIOS

ATCA-7350 Installation and Use (6806800G59G)

129

The menu represented in the following table is used to configure MPS Configuration options.

NOTE: Bold text indicates default setting.

6.9.2.7

Remote Access Configuration Submenu

To access this submenu, select Advanced on the menu bar, and then Remote Access
Configuration.

The menu represented in the following table is used to configure Remote Access Configuration
options.

Table 6-11 MPS Configuration Submenu

Feature

Options

Description

MPS Revision

1.1
1.4

Select MPS Revision.

Table 6-12 Remote Access Configuration Submenu

Feature

Options

Description

Remote Access

Disabled
Enabled

Enable/Disable Remote access function.

Serial port number

COM1

Select COM Port for remote access function.

Serial Port Mode

115200 8, n, 1
57600 8, n, 1
38400 8, n, 1
19200 8, n, 1
9600 8, n, 1

Select Serial Port settings.

Flow Control

None
Hardware
Software

Select Flow Control for console redirection.

Terminal Type

ANSI
VT100
VT-UTF8

Select the target terminal type.