Altera Arria V Avalon-ST User Manual
Page 92
Signal
Direction
Description
txdetectrx0
Output
Transmit detect receive
start a receive detection operation or to begin loopback.
txelecidle0
Output
Transmit electrical idle
electrical idle.
txcompl0
Output
Transmit compliance
disparity to negative in Compliance Mode (negative COM
character).
rxpolarity0
Output
Receive polarity
invert the polarity of the 8B/10B receiver decoding block.
powerdown0[1:0]
Output
Power down
power state to the specified state (P0, P0s, P1, or P2).
tx_deemph0
Output
Transmit de-emphasis selection. The Arria V Hard IP for PCI
Express sets the value for this signal based on the indication
received from the other end of the link during the Training
Sequences (TS). You do not need to change this value.
rxdata0[7:0]
(1)
Input
Receive data
on lane
rxdatak0
(1)
Input
Receive data >n>. This bus receives data on lane
rxvalid0
(1)
Input
Receive valid
data on
rxdata
rxdatak
phystatus0
(1)
Input
PHY status
PHY requests.
eidleinfersel0[2:0]
Output
Electrical idle entry inference mechanism selection. The
following encodings are defined:
• 3'b0xx: Electrical Idle Inference not required in current
LTSSM state
• 3'b100: Absence of COM/SKP Ordered Set in the 128 us
window for Gen1 or Gen2
• 3'b101: Absence of TS1/TS2 Ordered Set in a 1280 UI interval
for Gen1 or Gen2
• 3'b110: Absence of Electrical Idle Exit in 2000 UI interval for
Gen1 and 16000 UI interval for Gen2
• 3'b111: Absence of Electrical idle exit in 128 us window for
Gen1
2014.12.15
PIPE Interface Signals
4-55
Interfaces and Signal Descriptions
Altera Corporation