Delta MMC120 User Manual
Page 82
82
Set Mode Command
Character: M
Decimal: 77
Hexadecimal: 04D
Command Value: New MODE value
This command sets the
MODE
to the value in the
COMMAND VALUE
field.
Set Null Drive Command
Character: N
Decimal: 78
Hexadecimal: 04E
Command Value: Millivolts of Drive
The 'N' command sets the
Null Drive
to the value in the
COMMAND VALUE
field.
Set Null Drive to Integral Drive Command
Character: n
Decimal: 110
Hexadecimal: 06E
Command Value: Unused
This command sets the
Null Drive
to the current Integral Drive value.
Why Bother?
It is important that the Null Drive be set because it is used in
open loop mode
and
hard
stops
. The ‘n’ command should only be issued when the axis is
in position
and its speed
is zero.
Open Loop Command
Character: O
Decimal: 79
Hexadecimal: 04F
Command Value: Millivolts of Drive