Attempt to go beyond extend limit

This parameter error will occur whenever either a

Go

or

Relative Move

command

requests that the axis moves to a position beyond the

EXTEND LIMIT

. The

COMMAND POSITION

will be set to the

EXTEND LIMIT

. The move will continue if

the bits for the Parameter Error are cleared in the

AUTO STOP

word. To remedy this

problem:

Fix the control program to avoid issuing illegal commands.

If the

EXTEND LIMIT

is set incorrect, fix its value.

Attempt to go beyond retract limit

This parameter error will occur whenever either a

Go

or

Relative Move

command

requests that the axis moves to a position beyond the

RETRACT LIMIT

. The

COMMAND POSITION

will be set to the

RETRACT LIMIT

. The move will continue if

the bits for the Parameter Error are cleared in the

AUTO STOP

word. To remedy this

problem:

Fix the control program to avoid issuing illegal commands.

If the

RETRACT LIMIT

is set incorrect, fix its value.

Requested drive too large

This parameter error indicates that requested drive used by either an

Open Loop

command or a move command using

Quick Mode

is too large. The maximum allowed

drive is ±12000 millivolts, although values this large can easily cause an

Overdrive Error

.

Invalid command value

This parameter error is set if either the Integral Drive or Null Drive is set to a value

greater than ±10000 with the

Set Integral Drive

and

Set Null Drive

commands.

Invalid step number given in "Start Events" command

Because there are only 256 event steps—numbered 0 to 255—any

COMMAND VALUE

outside of that range with the

Start Events

command will generate this error.

Invalid scale value

This parameter error indicates that a

SCALE

was set to an invalid value: either 0 or

32768. If you are having a difficult time setting the

SCALE

parameter, you may want to

try

using the Scale/Offset Calibration Utilities

.