controller will allow as a

COMMAND VALUE

. (When the

SCALE

is negative, this is

the minimum value.) A

COMMAND VALUE

that exceeds this value will be set to the

EXTEND LIMIT, and the PARAMETER ERROR bit in the

STATUS

word will be set.

The EXTEND LIMIT is given in Position Units.

NOTE: The EXTEND LIMIT must be changed when the

SCALE

or

OFFSET

parameters are changed. Extending is the direction that gives increasing

TRANSDUCER COUNTS

.

NOTE:On startup, the EXTEND LIMIT defaults to the current position of the axis, so

new EXTEND and

RETRACT LIMITS

must be issued followed by a ‘P’

command before the axis will move, unless different limits have been saved in

the

FLASH

.

RETRACT LIMIT

Default: Current position on power-up

Range:

Valid 16-bit Position

The RETRACT LIMIT specifies the minimum value the motion controller will allow as a

position

COMMAND VALUE

. (When the

SCALE

is negative, this is the maximum

value.) A

COMMAND VALUE

below this value will be set to the RETRACT LIMIT.

The RETRACT LIMIT is given in Position Units.

NOTE:The RETRACT LIMIT must be changed when the

SCALE

or

OFFSET

parameters are changed.

NOTE:On startup, the RETRACT LIMIT defaults to the current position of the axis, so

new

EXTEND

and RETRACT LIMITS must be issued followed by a ‘P’

command before the axis will move, unless different limits have been saved in

the

FLASH

.

PROPORTIONAL GAIN

Default: 1

Range: 0 to 65535

The PROPORTIONAL GAIN specifies the amount of drive added to the output for each

unit of position error. It is defined as:
PROPORTIONAL GAIN = 0.1 millivolts per unit of Position Error
Proportional drive is defined as: