Link type - any axis status bits – Delta MMC120 User Manual
Page 137
137
1. Calculate the Link Type:
This involves converting the following bit fields into a hexadecimal byte. It is
highly recommended that the Link Type and Link Value popup dialog be used
instead of doing this manually. Use the following diagram to calculate the byte in
binary and then convert to hexadecimal or decimal and enter in the Link Type
field.
1
Axis 0 or 1
0 is
≤
, 1 is
≥
1 0
0 is Target Speed,
1 is Actual Speed
0
0
2. Enter the Limit (threshold) speed in the Link Value field.
Link Type - Any Axis Status Bits
Link Type: See below
Link Value: Bit pattern that must be set or cleared
Range: Any bits
These link types wait for at least one of a user-selectable group of Status Bits to be set or
cleared on the axis selected by the link type.
Using with the
Link Type and Link Value
Popup Dialog
1. Under Link Type Category, select Selected Axis (Enhanced).
2. Under Axis, select the axis you desire to monitor.
3. Under Link Type, select Status Bits.
4. Under Link Condition, select the appropriate option for whether you wish to wait
for one or more bits to be ON or OFF.
5. Under Link Condition, check the boxes next to the Status bits that you wish to
monitor with this link type.
Using without the
Link Type and Link Value
Popup Dialog
1. Calculate the Link Type:
This involves converting the following bit fields into a hexadecimal byte. It is
highly recommended that the Link Type and Link Value popup dialog be used
instead of doing this manually. Use the following diagram to calculate the byte in
binary and then convert to hexadecimal or decimal and enter in the Link Type
field.