beautypg.com

Delta MMC120 User Manual

Page 60

background image

60

G Current Output 2
H Common

J Current Output 1

Hardware Specifications

Inputs

Indicators

Input Impedance

Input voltage range

Overvoltage protection

Outputs

Output current range

Conversion Accuracy

Offset

Two per unit

1 dual color LED per channel;

Green = positive input,

Red = negative, intensity indicates

amplitude

40k

±

10V

±

100V (Outputs may reverse polarity if

inputs are above power supply voltages)

Two per unit

±

10mA to

±

100mA, switch-selectable (See

the Output Characteristics table for more

information)

0.6% full scale, typical, all ranges

0.05% typical,

±

100mA range

0.5% typical,

±

10mA range

Power Supply Requirements

Voltage

±

12 VDC to

±

15 VDC

Current

±

50mA plus load current (

±

250mA

maximum)

Isolation

There is no isolation between inputs,

outputs, and power supplies. If isolation

is required, it must be done external to the

VC2100 (Delta motion control modules

provide isolated voltage outputs).

Protection

Power supply inputs are protected against

over-voltage, spikes, and reverse voltage.

User should fuse with appropriate fast-

blow fuse.

Mechanical Specifications

Dimensions

Weight

Mounting

Connectors

0.94 x 2.94 x 3.94 in (2.4 x 7.5 x 10.0 cm)

3.5oz (100 g)

Mounts directly to DIN rail

Cage clamp terminal blocks integrated into

package

Environment

Operating temp.

Storage temp.

+32 to +140

°

F (0 to +60

°

C)

-40 to +185

°

F (-40 to +85

°

C)