Section 7
Programming
This section of the manual describes how to manually program the control panel from the built-in annunciator.
Each subsection discusses these menu options in detail. All options described in this section can be performed
using the Silent Knight Software Suite 5660.
7.1
UL 864 Programming Requirements
Important!
Before any customized programming is done, JumpStart should be run first. After JumpStart is run,
thoroughly test the system. The reason the system should be tested after JumpStart is because Jumpstart
automatically programs the system, searching for and configuring all SLC and SBUS devices it finds.
JumpStart allows you to confirm the integrity of the installation prior to performing any custom
programming. After determining that the hardware is properly installed, custom programming can be
performed. Refer to Section 6.
NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION,
AND OTHER INVOLVED PARTIES: This product incorporates field
programmable software. In order for the product to comply with the
requirements in the Standard for Control Units and Accessories for Fire Alarm
Systems, UL 864, certain programming features or options must be limited to
specific values or not used at all as indicated below.
Programming
Option
Menu Item
Permitted in
UL 864 (Y/N)
Possible
Settings
Settings
Permitted in
UL 864
Time Options
Low AC Report Delay Yes
0–30 hours
1–3
Display Oldest Event
Y (Enabled)
Yes
Yes & No
Yes
N (Disabled)
No
Yes & No
No
Alarm Verification
Alarm Verification
Yes
1-250
1-60