Juniper Systems Allegro DOS Manual User Manual
Page 190
Page 5-30 MS-DOS
❏ COM1 Output: RS-232 (not user editable)
This setting is reserved for future use.
❏ Memory Test: Off
The Memory Test validates that the memory is working okay. It takes
longer to boot up the Allegro when it is on, so it is best to only turn it
on occasionally and leave it off most of the time.
❏ Battery Capacity: 2500 - 4500 mAh (not user editable from Setup)
This field displays the current setting for battery capacity in milliamp-
hours. This setting effects the gauging circuitry and should be set to
accurately reflect the capacity rating of the NiMH rechargeable
battery pack in use. It can only be set in the popup window that is
invoked when the battery is replaced. Refer to Section 2, Hardware
Features, Batteries for details.
❏ Vehicle Mode: On or Off
Vehicle Mode should be turned on when the Allegro is connected to a
vehicle’s power supply. The battery charge management is adapted
for continuous external power, preventing the NiMH battery pack
from being overcharged. Refer to Section 2, Hardware Features, Batteries
for details.