Juniper Systems Archer 2 Addendum User Manual
Non-incendive archer 2 rugged handheld, Non-incendive approval, Read this document
Non-incendive Archer 2 Rugged Handheld
P/N 24735-00. Copyright December 2014, Juniper
Systems, Inc. All rights reserved. Information is
subject to change without notice. Archer 2 Rugged
Handheld is a trademark of Juniper Systems, Inc.
tel: 435.753.1881
l
web: www.junipersys.com
1132 W. 1700 N. Logan, UT 84321
WARNING – EXPLOSION HAZARD –
In Hazardous Locations:
Do not dock the Archer 2
Do not change or charge batteries
Do not insert or remove cards
Do not connect or disconnect any device or
cable
In hazardous locations, the battery door must be in
place as indicated below:
Avertissement – Risque D’Explosion – Dans des
zones dangereuses:
N’amarrez pas l’unité, ne changez pas et ne
chargez pas les batteries, n’insérez et ne retirez
pas de cartes et n’établissez ni ne rompez
aucune connexion
Les caches de protection des ports et des
batteries doivent toujours rester installés
WARNING – EXPLOSION HAZARD –
Servicing:
Substitution of components may impair suitability
for Classes I, II, III Division 2.
Avertissement – Risque D’Explosion –
La substitutiond e composantsp eutr endre ce
materiel inacceptable pour les emplacements de
Classes I, II, III Division 2.
4010677
Non-incendive Approval
The non-incendive Archer 2
Rugged Handheld™ from Juniper
Systems, Inc. is Intertek Laboratory
approved Non-Incendive Class I,
Class II, Class III Division 2.
The non-incendive Archer 2 may be
used in hazardous locations where
ignitable concentrations of flammable gases,
vapors or liquids are not part of the normal
environment, but can become so under unusual
circumstances.
Category
Specification
Model AR2 Series
Electrical Rating +12VDC, 1.5A
Battery Type Li-Ion (only use the batteries
specified in the Archer 2
Owner’s Manual, P/N 23716
and 24472)
Classes
Division
Groups
Countries
Conforms to ANSI/ISA Std
and UL Std
Certified to CAN/CSA Std
IP Rating for Outdoor Use
I, II, and III
2
A, B, C, D, F, G
US and Canada
12.12.01-2013
60950-1
C22.2 Nos. 25, 213 & 60950-1
Applicable to the battery
and main compartments.
The connector I/O module
does not have an IP rating.
Read This Document
Read this document to learn how to safely operate
the non-incendive Archer 2
Rugged Handheld in potentially
hazardous locations.
This addendum is a supplement to
the Archer 2 Owner’s Manual.
Note: The Archer 2 Owner’s
Manual is available on our
website a
Using the Archer 2 Rugged Handheld in a
Hazardous Location
The rules (warnings) that follow must be followed to
maintain the Intertek Laboratory approved non-
incendive standard and to prevent the possibility of
serious injury.