46 - Initial Configuration

DeviceMaster Installation and Configuration Guide: 2000594 Rev. A

Uploading SocketServer with PortVision DX

4.

Click Yes to the Upload Firmware message that warns you that this is a
sensitive process. It may take a few moments for the firmware to upload onto
the DeviceMaster. The DeviceMaster reboots itself during the upload process.

5.

Click Ok to the advisory message about waiting to use the device until the
status reads ON-LINE. In the next polling cycle, PortVision DX updates the
Device List pane and displays the new SocketServer version or right-click the
DeviceMaster and click Refresh.

6.

If the upload fails, reset the Bootloader timeout to 60 seconds and then repeat

Steps 3

through 5. For procedures, see

Changing the Bootloader Timeout

on

Page 115.

You are now ready to continue the installation and configuration process.

Device Driver (NS-Link) Installation

on Page 51

Socket Port Configuration

on Page 65