Changing the bootloader timeout – Comtrol Hub DeviceMaster User Manual
Page 115
DeviceMaster Installation and Configuration Guide: 2000594 Rev. A
Managing the DeviceMaster - 115
Managing the DeviceMaster
Changing the Bootloader Timeout
If SocketServer fails during the upload process, you should change the Bootloader
timeout value to 45 seconds.
Note: The DeviceMaster must be able to communicate using an IP address, which
is compatible with this local network. If necessary, refer to
You must meet these requirement to use this procedure.
•
NS-Link device driver assembly v10.xx or higher installed
•
SocketServer v9.xx or higher loaded on the DeviceMaster
•
PortVision DX installed
Note: If you cannot meet these requirements, you can use RedBoot to change the
Changing the Bootloader Timeout
Use the following procedure to change the Bootloader timeout to 45 seconds. You
can use this procedure to return the Bootloader timeout to 15 seconds after you
have successfully uploaded SocketServer.
1.
If necessary, start PortVision DX, from Programs> Comtrol > PortVision DX >
PortVision DX.
2.
Right-click the DeviceMaster in the Device Tree or Device List pane and click
Properties.
3.
Type 45 in the Bootloader Timeout text box and click Apply.
Note: You should return the Bootloader Timeout value back to 15 seconds after
you upload SocketServer.