Troubleshooting and Technical Support

149.

General Condition

Explanation/Action

PWR or Status LED
flashing

Indicates that the bootloader has not downloaded to the
DeviceMaster.

1.

If applicable, remove the NS-Link driver.

2.

Make sure that you have downloaded the most
current driver:

ftp://ftp.comtrol.com/dev_mstr/rts/

drivers/

.

3.

Install the latest driver and configure the
DeviceMaster using the MAC address. Make sure
that you reboot the system. See

Device Driver (NS-

Link) Installation

on Page 51 for procedures.

Note: If the PWR or Status LED is still flashing, contact

Technical Support.

PWR or Status LED not
lit

Indicates that power has not been applied or there is a
hardware failure. Contact Technical Support.

Can ping the Comtrol
device, but cannot open
the ports from a remote
location.

(You must have
previously programmed
the IP address, subnet
mask, and IP gateway.)

The NS-Link driver uses Port 4606 (11FE h) to
communicate with the DeviceMaster.

When using a sniffer to track NS-Link packets, filtering
for Port 4606 will easily track the packet. The packet
should also contain the MAC address of the device and
the originating PC so that it can be determined if the
packet is able to travel the full distance one way or not.

If the 4606 packet is found on one side of a firewall or
router, using sniffer, and not on the other side, then that
port needs to be opened up to allow the 4606 to pass.

This will most often be seen with firewalls, but is also
seen in some routers.

Cannot ping the device
through Ethernet hub

Isolate the DeviceMaster from the network. Connect
the device directly to the NIC in the host system.

Cannot ping or connect
to the DeviceMaster

The default DeviceMaster IP address is often not
accessible due to the subnet masking from another
network unless 192.168 is used in the network.

In most cases, it will be necessary to program in an
address that conforms to your network. See

Configuring

the Network Settings

on Page 40 to use PortVision DX to

program the IP address.

If you do not use PortVision DX (or the NS-Link driver
for Windows) to program the IP address, you can use
RedBoot.

If you use RedBoot, you only have 15 seconds to disable
the Bootloader with RedBoot to get into the setup
utility. See

RedBoot Procedures

on Page 129 for the

RedBoot method of programming an IP address.