Managing the devicemaster, Rebooting the devicemaster – Comtrol Hub DeviceMaster User Manual
Page 103
DeviceMaster Installation and Configuration Guide: 2000594 Rev. A
Managing the DeviceMaster - 103
Managing the DeviceMaster
This section discusses the following DeviceMaster maintenance procedures:
•
•
Uploading SocketServer to Multiple DeviceMasters
•
Configuring Multiple DeviceMasters Network Addresses
Note: You can configure the network addresses for multiple DeviceMasters,
configure common settings for the DeviceMasters, and save the settings
to a configuration file that you can use to load settings up to all or
selected DeviceMasters.
•
Adding a New Device in PortVision DX
•
Using SocketServer Configuration Files
•
Using Driver Configuration Files
•
Changing the Bootloader Timeout
on Page 115, which discusses changing the
Bootloader timeout
•
on Page 116, which also discusses checking the
Bootloader version and downloading the latest Bootloader
•
•
Restoring Factory Defaults (2-Port, Only)
•
Accessing SocketServer Commands in Telnet/SSH Sessions (PortVision DX)
•
Accessing RedBoot Commands in Telnet/SSH Sessions (PortVision DX)
Note: You can optionally refer to
on Page 129 if you want to
perform procedures at the RedBoot level.
Rebooting the DeviceMaster
There are many ways to reboot the DeviceMaster.
Method
Procedure
PortVision DX
Right-click the DeviceMaster or DeviceMasters in the Device
List pane, click Advanced >Reboot and then Yes.
Note: If security has been enabled in the web page, you will
need to reboot the DeviceMaster in the web page.
Web page
Main page (Server Status): Scroll to the bottom of the page,
click Reboot and then Yes: Reboot.
Telnet
Type reset.
DeviceMaster
2-Port Models
DeviceMaster 2-port models have a Reset/Restore switch.
•
If the Reset/Restore switch is depressed for less than 2
seconds, the DeviceMaster 2-port models reboots.
•
If the Reset/Restore switch is depressed for greater than
approximately 5 seconds it restores the DeviceMaster to
the factory default values.