Clearing the flash, Clearing eeprom, Telnet access – Comtrol Hub DeviceMaster User Manual

Page 174: Clearing the flash clearing eeprom

background image

174 - Troubleshooting and Technical Support

DeviceMaster Installation and Configuration Guide: 2000594 Rev. A

Troubleshooting and Technical Support

The EEPROM memory is programmed with a number of default values. The
values that you can modified are shown in the following table.

Clearing the Flash

The flash only has program binaries. There is no user data stored in the flash. If it
is necessary to erase the binaries, the default application (SocketServer.bin) can be
erased using the fis init command from the DeviceMaster using a serial connection,
that is Port 1 through a null-modem cable and a COM port.

See

Establishing a Serial Connection

on Page 130 (

Steps 1

through 6) to access

RedBoot and enter fis init -f at the RedBoot prompt.

There is no easy way to remove the bootloader binary. Removal of the bootloader
binary would leave the DeviceMaster inoperable and require that it be returned to
the factory to be reprogrammed.

Clearing EEPROM

The user configurable values in the EEPROM, can be accessed and set in three
different ways. All of the values can be set using a serial connection (Port 1 with a
null-modem cable connected to a COM port). Most of the values can be accessed by
using the Web Server (SocketServer or NS-Link equivalent) or telnet. Refer to the
appropriate procedure for your situation:

Telnet Access

Serial Port Access

on Page 175

Web Server Access

on Page 175

Telnet Access

Use this procedure to access the DeviceMaster configuration through telnet,

Note: To reset authentication, see

Serial Port Access

on Page 175 or use the

RedBoot Command Overview

on Page 135.

1.

Open a telnet session, enter the DeviceMaster IP address. If using Windows,
open a Command window and type telnet [ip_address].

Note: Press the Enter key if you have not programmed a password or use the

password previously configured. The DeviceMaster does not come pre-
programmed with a password.

2.

To return the IP address to the default value, type ip 192.168.250.250 255.255.0.0
192.168.250.1
and press Enter.

3.

To reset the password, type password and press Enter.

4.

To reset the telnet timeout value, type teltimeout 300 and press Enter.

Parameter

Name

Default Value

User

Configurable

Web or

Telnet

Console

Port

Port

Authentication None

Yes

No

No Yes

IP Address

192.168.250.250 Yes

Yes

Yes

Yes

IP Mask

255.255.0.0

Yes

Yes

Yes

Yes

IP Gateway

192.168.250.1

Yes

Yes

Yes

Yes

Password

Blank

Yes

Yes

No

Yes

Telnet

Enable

Yes

Yes

Yes

Yes

Telnet Timeout 300 sec.

Yes

Yes

Yes

Yes

Bootloader
Timeout

15 sec.

Yes

Yes

Yes

Yes

SNMP

Enable

Yes

Yes

Yes

Yes

SSL

Disable

Yes

Yes

Yes

Yes

SSL is a security feature available with SocketServer v7.00 and later.