16 - Hardware Installation

DeviceMaster Installation and Configuration Guide: 2000594 Rev. A

Hardware Installation

1-Port - Enclosed Installation

Use the following procedure to install the DeviceMaster 1-Port.

1.

Place the 1-Port on a stable surface and skip to

Step 2

or optionally mount the

DeviceMaster using the mounting flanges or DIN rail adapters.

a.

Pick up the DeviceMaster so that the front of the device is facing you.

b.

Pick up a DIN rail clip. (The three tines should be on top
and the M4 label should face you.)

c.

Slide the DIN rail clip behind the DeviceMaster and line
it up with one of the screw holes on the DeviceMaster.

d.

Insert the M4 screw into the hole and tighten with a
Phillips screwdriver.

e.

Repeat

Steps b

through d with the second DIN rail clip.

Make sure the screws on both DIN rail clips line up.

Note: If you need to remove the DeviceMaster from the

DIN rail, exert pressure on the backside of the
tabs at the bottom of both DIN rail clips.

f.

Attach the DeviceMaster to the DIN rail.

Note: Do not connect multiple units until you have changed the default IP

address, see

Initial Configuration

on Page 35.

2.

Connect the DeviceMaster port labeled 10/100 ETHERNET to the same
Ethernet network segment as the host PC using a standard network cable.

If you plan on using the NS-Link device driver, make sure that you do
not connect RS-422/485 devices until the appropriate port interface
type has been configured in the driver. The NS-Link default port
setting is RS-232.

3.

Apply power to the DeviceMaster using the appropriate procedure for your
power supply.

Note: The supported input voltage (5VDC or 5-30VDC) is printed on the

DeviceMaster.

5VDC Power Supply (Barrel Connector)

Connect the 5VDC power supply to the DeviceMaster and to a power outlet.

Go to

Step 4

to verify that the DeviceMaster is functioning properly.

5-30VDC with Screw Terminal Power Connector

Use the following procedure power on this model.

Observe proper ESD techniques when connecting and disconnecting
the DeviceMaster.

Insert the earth ground wire into the earth ground screw terminal.