background image

DeviceMaster Installation and Configuration Guide: 2000594 Rev. A

Hardware Installation - 29

Hardware Installation

4.

Verify that the PWR LED has completed the boot cycle and network
connection for the DeviceMaster RTS is functioning properly using the table
below.

5.

Go to

Initial Configuration

on Page 35 for default network settings and how to

configure the DeviceMaster for use.

DeviceMaster RTS 16-Port (External Power Supply) LED Descriptions

Red
LED

Red LED on the front panel of the DeviceMaster is lit, indicating you
have power and it has completed the boot cycle.

Note: The LED flashes while booting and it takes approximately 15

seconds for the Bootloader to complete the cycle. When the
Bootloader completes the cycle, the LED has a solid, steady light
that blinks approximately every 10 seconds.

LNK
ACT

The red LNK ACT LED is lit, indicating that
you have a working Ethernet connection.

COL

If the red COL LED is lit, there is a network
collision.

100

If the red 100 LED is lit, it indicates a
working 100 MB Ethernet connection (100
MB network, only). If the LED is not lit, it
indicates a 10 MB Ethernet connection.

Note: For additional LED information, go to the

Status LED table

on Page 150.

LNK

ACT
COL
100

10/100 NETWORK

UP

DOWN