Returning the devicemaster to factory defaults – Comtrol Hub DeviceMaster User Manual
Page 173
DeviceMaster Installation and Configuration Guide: 2000594 Rev. A
Troubleshooting and Technical Support - 173
Troubleshooting and Technical Support
14. Click Telnet, leave Port 23 as the Selected Port and click Ok
15. Press Enter at the Password prompt.
16. Enter secureconf disable and press Enter.
17. Enter securedata disable and press Enter.
Returning the DeviceMaster to Factory Defaults
The DeviceMaster uses two types of memory, volatile and non-volatile. The
volatile memory is in the form of DRAM and SRAM. They are used for program
execution and buffers. Clearing the volatile memory, as its name suggests,
requires powering off the DeviceMaster.
The non-volatile memory is in the form of flash and EEPROM memories.
The flash memory is used for non-volatile program storage. Leaving the factory,
there are two programs stored in the flash:
•
Bootloader binary
The bootloader binary is loaded into DRAM for execution, when the device is
turned on. After a period of time, the bootloader loads the default application,
•
Default application binary
SocketServer or in some instances, a customer written custom application,
into DRAM and it starts execution. It continues until the unit is powered off.
The only access you have to the binaries is if they decide to load a newer version. If
this is done, the newer version overwrites that piece of flash. No user data is ever
entered here.