Connecting to a CV-5001 Series Controller

After connecting the CV-5001 Series controller to the computer on which this software is installed, start up
the software and then set the connection points.

Before Connecting

Confirm the following settings for the CV-5001 Series controller and the computer.

Network settings

Set the information needed for an Ethernet connection in network settings. These settings include IP address,
subnet mask and port number. Refer to the user’s manuals for the computer and CV-5001 Series controller for
more information.

Refer to "CV-5001 Series User’s Manual".

Data output settings (CV-5001 series)

Start up the CV-5001 Series controller, then confirm that the data output settings are operating correctly. Refer to
the CV-5001 Series controller manual for more information.

Refer to "CV-5001 Series User’s Manual".

Note

When connecting to a computer, set the CV-5001 Series controller to Run mode. However, Program mode can also be used

while the "Captured screens" or "Communication terminal" is used.

Connect via Ethernet to perform continuous data transmission.

Using a USB or RS-232C connection in a high-load environment where data is constantly transferred can cause errors in

transmission.

When this software is used in combination with an Ethernet PLC link communication, data may not be saved due to the high

load on the CV-5001 controller.