beautypg.com

KEYENCE CV-H5N User Manual

Page 135

background image

4

CV-H5N-M-WW-NO4-E

4-51

2

Select [Connected CV] for [Read From].

Connected CV

Select this to read the program data from a CV-5001

Series controller connected to the computer.

File

Select this to read the program data from a folder within

the computer.

3

Select [Read from].

CV internal memory

Select this to load a program from the internal memory

of the connected CV-5001 controller.

CompactFlash card in the CV

Select this to load a program from the CompactFlash

card currently in the CV-5001 controller.

Current program

Select this to specify the program number currently in

use. (See steps 3 and 4.)

4

Select the [Program no.].

This is available when [CompactFlash card in the CV] or [CV
internal memory] has been selected in step 2.

5

Select [Read to].

Drive C of Virtual CV

Select this to load data to the virtual C drive of the

simulator.

Drive D of Virtual CV

Select this to load data to the virtual D drive of the

simulator.

6

Select [Program no.].

The default setting is the program number currently being
used by the simulator.