KEYENCE CV-H5N User Manual
Page 135
4
CV-H5N-M-WW-NO4-E
4-51
2
Select [Connected CV] for [Read From].
•
Connected CV
Select this to read the program data from a CV-5001
Series controller connected to the computer.
•
File
Select this to read the program data from a folder within
the computer.
3
Select [Read from].
•
CV internal memory
Select this to load a program from the internal memory
of the connected CV-5001 controller.
•
CompactFlash card in the CV
Select this to load a program from the CompactFlash
card currently in the CV-5001 controller.
•
Current program
Select this to specify the program number currently in
use. (See steps 3 and 4.)
4
Select the [Program no.].
This is available when [CompactFlash card in the CV] or [CV
internal memory] has been selected in step 2.
5
Select [Read to].
•
Drive C of Virtual CV
Select this to load data to the virtual C drive of the
simulator.
•
Drive D of Virtual CV
Select this to load data to the virtual D drive of the
simulator.
6
Select [Program no.].
The default setting is the program number currently being