KEYENCE CV-H5N User Manual
Page 134
4
CV-H5N-M-WW-NO4-E
4-50
Reading and Writing Program Data from a CV-5001 Series Controller
■ Loading program data from a connected CV-5001 Series controller
1
Select [Transfer programs] from the [Simulator] menu.
The [Transfer Programs] menu appears.
Note
This function is not available while collecting data.
Suspend data collection before proceeding with the simulator.
Select the [Read from cv] tab.
1
Information about [File type] is displayed.
•
Read From
Select either [Connected CV] (connected CV-5001 Series controller) or [File] (a program file in a folder
within the computer). (See step 2.)
•
Connected CV
The connection point selected in [Connect to] of [Name/Connected CV] under [Virtual CV Settings] is
displayed.
•
Read from / Program no.
This specifies which Program No. will be read from the CV-5001 Controller (See steps 2 and 3)
•
File type
The type of data file that will be transferred with the Program No. By default, [Program Data], [Registered
image], and [Library Data] are on.
Refer to the CV-5001 Series controller "User’s Manual" for more details about a specific item.
Note
As a rule, the file should be read using default values (Program data/Registered image/Library data is on, Global data is off).
2
Information about [Read to] is displayed.
•
Virtual CV
The name of the selected Virtual CV is displayed.
•
Save to target / Save to program number
This specifies the program number and the save location. (See steps 4 and 5)
1
2
3
4
5
2
1
6