Verifying cv-5001 series controller output data – KEYENCE CV-H5N User Manual
Page 111
4
CV-H5N-M-WW-NO4-E
4-27
Verifying CV-5001 Series Controller Output Data
Verifies all output data configurations from the CV-5001 Series controller with all current data on the CV-5001
Series controller. If the two data sets do not match, data transfer will not operate properly.
1
Select [Batch-verify output data] from the [Data
Collection] menu or click the [Batch-verify output data]
icon in the toolbar.
The [Verify Output Data] window is displayed. A message
reading "(Connection point): Verifying output data" appears.
Reference
•
If there is no current output configuration data for the CV-5001
controller stored in the software, the settings from the connected
CV-5001 controller will be read.
•
If there is an error in the validation, a message saying
"(Connection Point Name): Difference found in output data.
Initialize settings and read new output settings data?" will appear.
To load in current CV-5001 Series controller setting data, click
[OK]. To continue with the current CV-5001 controller data, click
the [Cancel] button.
Note
It is necessary to verify the output configuration data whenever a
change has been made in the [Output] menu of the CV-5001 Series
controller. Data transfer may not occur if the CV-5001 output
configuration does not match that of the software.
2
Click the [OK] button when the output data has been
verified to return to the main window.