There are 8 differences between the simulator and the physical device.

1. Measurement time / trigger delay

The hardware architecture of the computer and the device are different, so the same process may take a
different amount of time on one than on the other.

2. External input/output

General evaluations, terminal output, PLC- EIP - RS-232C, Ethernet, USB, and image output (except the memory
card) are not functional.
Output to SD2 acts as output to the Virtual CV D drive.

3. Image archive (utility)

No history is kept.

4. File manager (utility)

Unavailable.

5. Transferring programs and settings (global settings)

Unavailable.

6. Multi-Image Capture

The Multi-Image capture will not function if activated in the simulator. Normal measurement will be taken.

7. “Read” and “Write” under "Library settings" in OCR mode

Unavailable.

8. Differences in measurement results due to differences in hardware.

The differences between the calculation hardware in the PC and the device may result in the following
differences in measurement results.

Recognition levels when library registration has been used in OCR or the simulator

Digits two or more places after the decimal point in edge intensity and all forms of edge mode

Digits two or more places after the decimal point in concentration detection mode and average concentration

9. Differences in camera settings

Shutter speed, light intensity, or gain adjustment is not applied.

The trigger delay is not applied.

The continuous update of the window update mode is not applied.