47

Chapter 4

Fault Location Mode

Fault location identifies the position of impedance discontinuities
(reflections) within the antenna/feeder system. The measurement
results are displayed on an x-y graph. Distance from the Site Analyzer
is shown on the x-axis, while relative magnitude of the discontinuity is
shown on the y-axis.

Before you make a fault location measurement, be sure that you have
the following items and information:

A Bird Calibration Combination (Cal Combo) calibration unit

All necessary cables and adapters of the correct size and con-
nector type.

The velocity of propagation for the cable type you will measure
(obtain from the cable manufacturer)

Number of data points to use in making the distance to fault
measurement (user choice)

This chapter describes how to make a fault location measurement and
provides step by step instructions. In addition, this chapter also
describes how to set and move markers. For information and instruc-
tions to save and recall traces, refer to Save and Recall, page 79.

To make a fault location measurement, follow the procedures in this
chapter in the order they are presented.

Determine the Power of the Component Being Tested

Use a service monitor, power meter, or spectrum analyzer to check that
the component being tested does not have power greater than +22 dBm.

CAUTION

+22 dBm max. input

Do not apply RF power to the Antenna Test Port.

Exceeding the maximum input will damage the Site

Analyzer.