Figure 10 setting a limit line – Bird Technologies SA-6000EX User Manual
Page 46
Bird Technologies
30
Figure 10 Setting a Limit Line
Step
Action
1
While in the Measure Match mode or the
Fault Location mode, press the Limit Test
key:
First press - Test ON Aud (line and sound)
Second press - Test ON (line only)
Third press - Test OFF
2
Press the Config key
3
Press the Limit Line softkey
4
Use the keyboard to enter a limit value of
your choice or use the suggested limits
listed below (use the +/- key to enter a nega-
tive value) then press the Enter key.
Antenna at resonance
-14 dB
Connectors
-25 dB
Jumpers
-35 dB
Lightning protector
-25 dB
Transmission lines
-30 dB
5
Press the Esc key to exit the configure
screen
This manual is related to the following products: