beautypg.com

Troubleshooting – Bird Technologies SA-6000EX User Manual

Page 142

background image

Bird Technologies

126

Troubleshooting

Any service procedure not covered in this manual should be referred to
an authorized service facility.

Locate the problem, review the possible causes, and perform the
action listed. If the problem is not corrected, give us a call or return
the unit for service.

Problem

Possible Cause

Possible Correction

Unit will not power up Battery pack drained

Charge the battery pack.

Battery pack unable to

keep a charge

Replace the battery pack.

AC adapter is damaged Replace the ac adapter.

Self test fails

Error condition

Turn the unit off and then

back on. If the problem

persists, return the unit

for service.

Date and time appear,

hiding the display

Internal error

Press

Mode

,

Utility

,

and then

Escape

.

Fault Location trace

appears incorrect

Scale too large

Press

Auto Scale

to

make the scale smaller.

Incorrect cable loss or

velocity of propagation

Check the cable loss and

V

p

settings.

Erratic antenna test

measurements

Bad calibration combo

Use a different calibration

combo.

softkeys beep when

pressed without

performing any

function

Context switching

operations taking place

Wait for screen changes to

complete before.

Keys do not respond

Unit is “Locked Up”

Turn the unit off and then

back on.

Perform a full system

initialization. Disconnect

the AC adapter, hold down

the Contrast key and turn

the unit off. Turn the unit

back on.

Limit line disappears

in Fault Location

Limit line not drawing

Turn the limit line off and

then back on.