Setting the offset, 5011-ef – Bird Technologies SA-6000EX User Manual
Page 130
Bird Technologies
114
Setting the Offset
To read unattenuated power when using a coupler or attenuator,
enter (in dB) the attenuation or coupling factor. To convert percent-
ages to dB, use the equation:
Attenuation (dB) = 10 x Log
10
[Attenuation (%) / 100]
5011-EF
The Bird 5011-EF uses frequency-dependent correction factors to pro-
vide more accurate measurements. To use these, look at the label on
the side of the sensor and find the correction factor at the frequency
being measured. Add the correction factor to the other attenuation or
coupling factors, and enter this as an offset in the Site Analyzer.
Press from
Measure
Power Mode
Scroll to
Offset
Enter the
new value
This manual is related to the following products: