Setting the Offset

To read unattenuated power when using a coupler or attenuator,
enter (in dB) the attenuation or coupling factor. To convert percent-
ages to dB, use the equation:

Attenuation (dB) = 10 x Log

10

[Attenuation (%) / 100]

5011-EF

The Bird 5011-EF uses frequency-dependent correction factors to pro-
vide more accurate measurements. To use these, look at the label on
the side of the sensor and find the correction factor at the frequency
being measured. Add the correction factor to the other attenuation or
coupling factors, and enter this as an offset in the Site Analyzer.

Press from

Measure

Power Mode

Scroll to

Offset

Enter the

new value