Battery Replacement

1. Lay the Site Analyzer, display side down, on a clean surface.
2. Remove the four screws and the battery cover. Refer to the picture

below.

Note:

Check the direction of the notch in the battery cover.

It is important to replace the cover the same way it was
removed.

.

3. Disconnect and remove the old battery pack from the battery

compartment.

4. Compare the connectors of the old and new battery packs. Make

sure that they have the same number of pins.

Note:

The battery pack in non-EX models are terminated

with a 2-pin connector. See “Parts List” on page 136 for infor-
mation regarding the proper battery pack to use with specific
models.

5. Install the new battery. Make sure the battery connector is firmly

connected to the circuit board connector.

6. Place the battery in the battery compartment. Make sure the

battery is flat in the compartment, and will not damage any wires
when the cover is installed.

7. Replace the battery cover and the screws.
8. Connect the AC adapter to the unit.
9. Apply power to the unit and verify that it operates properly
10. Charge the battery if required